1 General[edit | edit source]

Adam & Eva will be used for the safety covers in the Extrusion Area (Mex + Coex).

2 Pairing[edit | edit source]

  1. Remove Eva from the range of Adam.
  2. Remove the Power Supply at Pin 1 from Adam Unit
  3. Connect +24V to Pin 2 and 4
  4. Connect the Power Supply to Pin 1 at Adam Unit
  5. After 5-10s the LED will change to green, after this remove immediately Pin 2 and 4 from the +24V
  6. The Adam Unit will be reset and the LED will be red
  7. Continue with the normal commissioning from the Adam unit.

ATTENTION: If Pin 2 and 4 from Adam Unit will be not removed within the 5-10sec, the Unit will change in the fail-safe-mode and the LED will blink very fast. Then you need to repeat the step above.