1 General[edit | edit source]
Adam & Eva will be used for the safety covers in the Extrusion Area (Mex + Coex).
2 Pairing[edit | edit source]
- Remove Eva from the range of Adam.
- Remove the Power Supply at Pin 1 from Adam Unit
- Connect +24V to Pin 2 and 4
- Connect the Power Supply to Pin 1 at Adam Unit
- After 5-10s the LED will change to green, after this remove immediately Pin 2 and 4 from the +24V
- The Adam Unit will be reset and the LED will be red
- Continue with the normal commissioning from the Adam unit.
ATTENTION: If Pin 2 and 4 from Adam Unit will be not removed within the 5-10sec, the Unit will change in the fail-safe-mode and the LED will blink very fast. Then you need to repeat the step above.