1 DYNA-4-3.5C-15/46 (without safety output)[edit | edit source]
Use this electrical drawing to connect the Dynisco DYNA-4.
File:ElectricalDrawing Dynisco DYNA-4.jpg
2 DYNA-4-3.5C-15/46-GC8 (with safety ouput)[edit | edit source]
Use this Drawing to connect the Dynisco DYNA-4-8GC.
File:ElectricalDrawing Dynisco DYNA-4-GC8.jpg
2.1 Safety Maximum Output[edit | edit source]
The "safety maximum output" of the Dynisco will switch from 1 to 0, if the actual pressure has reached 80% of the nominal pressure (this is defined in the type key ...GC8, the number stands for the limit/10. This is set by the manufacturer and can not be changed.
Note: The Nominal-Pressure is written on the Dynisco Pressure Sensor. (e.g. DYNA-4-3.5C-15/46-GC -> 3.5C => 350 bar)
So the switchpoint for the safety output is 80% * 350 bar = 280 bar.