1 Description[edit | edit source]
We use perma STAR CONTROL TIME for long-time lubrication of the OSWALD motors at TDO Outlet. New device is Klübermatic STAR CONTROL (Klüber)
Oswald Motor:
Lubrication time for A-Side bearing 6 months and B-Side Bearing 12 months;
A-side == DRIVE END == SHAFT
B-side == NON DRIVE END
2 Electrical PinOut[edit | edit source]
3 Settings older device version with DIP-Switches[edit | edit source]
3.1 LED Status Codes[edit | edit source]
3.2 Circuit board settings[edit | edit source]
-
Dip Switch Settings
-
Table of cartridge and Time settings
Pause time
This means:
If we have 250ml-Cartridges and we have set the A-side to 6 month discharge time, we expect a discharge event approx. every 9:17 hours.
One discharge cycle uses up 0.53ml.
250ml/0.53ml == 472 cycles to empty the cartridge.
4 Settings current device version with display (Klübermatic STAR CONTROL)[edit | edit source]
The device is configured using the display on top.
Time/Impulse Mode:
We use TIME mode.
Press and hold button for 5 seconds to enter configuration until TIME and IMPULSE are flashing. Release button and press again one time to activate TIME mode.
Wait 3 seconds to enter next menu.
Cartridge Size:
Use button to select LC 250 ==250ml cartridge.
Wait 3 seconds to enter next menu.
Discharge Time:
Use button to select discharge time in month.
A-side: 6 months
B-Side: 12 months
4.1 Purge Mode[edit | edit source]
the new device offers a Purge Mode.
This is very helpful during first installation and after replacement of a cartridge to purge out the air of the device.
For this press the set-button for 10 seconds until "PU" is displayed.
The device will make three lubrication pulses.
Purge mode can be interrupted by pressing the button again.