1 Download Configurations with Sensor Tool[edit | edit source]
- Connect the RS485 on X3 of the amplifier box of Micro Epsilon
- Choose for Sensor Group induSENSOR
- Choose for Sensor Type induSENSOR MSC7401
- Hook the checkboxes and press the search symbol
- Start Data Transfer of the sensor -> Info -> Import Settings (InduSensor_MSC7401.csv)
location:\\Kom\_engineering\public\sensors\Micro-Epsilon\InduSensor_MSC7401.csv
- Now you should see the following configuration
2 Exchange a faulty Sensor Sleeve[edit | edit source]
- Go online with the Sensor Tool like as it´s mentioned above
- Change to the Single Value-Window
- Open the Screws of Sensor Sleeve and surveyor-staff
- Push the sleeve without distance peace against the support and re-tight the Sensor Sleeve on 4mA
- Move the surveyor-staff to the previous good value of the PVSS-Trend and tight it again
- Now you should be able again to move the Relax-System
- Move the faulty side to 0mm Stroke and take care that the new surveyor-staff shows 0mm again