Last edited 2 months ago
by Max Mustermann

Sinamics brake control



Template:Infobox bms


1 Sinamics brake control hardware[edit | edit source]

DC/AC motor modules do have to terminals on the motor connector for controlling a motor break with 24VDC AC/AC motor modules do not have this terminals, therefore CU-IOs are used, this special function can be used by selecting

MotBrake = "SeqCtlBico" ' "SeqCtlDrive", "SeqCtlBico", False

2 Sinamics brake control logic[edit | edit source]

Normally the brake is controlled by the sequence control of the drive. Detailled information is shown in FP -2701- because we use normally p1215 = 1 in LH1. To check the function make a trace with the following signals:

File:Sinamics Brakecontrol trace settings.JPG


Switch on => open the brake: After magnetizing is finished the brake opens that means, command close = FALSE + command open = TRUE

In order to show bit status please refer to Bittracks Bittracks

File:Sinamics Brakecontrol trace open.JPG


Switch off => close the brake: After drive is switched off the brake closes immediately, command close = TRUE + command open = FALSE, after the brake has closed and the waiting time has elapsed the pulses will be disabled

File:Sinamics Brakecontrol trace close.JPG