THYRO-AX controller

Template:Infobox bms

1 Application[edit | edit source]

MDO IR Heating at PET lines. Newer Lines should come with IR-Heaters from Carlo Gavazzi: https://kiwi.brueckner.com/mediawiki/index.php/Public:Carlo_Gavazzi_IR-Heater

2 Modules[edit | edit source]

2.1 Thyristor power controller[edit | edit source]

The thyro-AX controller is a component which may only be used to control and regulate electric energies in industrial alternating or three-phase networks. The Power Unit is suited for single phase loads.

2.2 Bus module Profinet[edit | edit source]

The Ethernet bus module can connect up to 8 power controllers of type Thyro-A, type Thyro-AX 1A and type Thyro-S with a master. Several bus modules can be used on one system.

3 Terminal Connection[edit | edit source]

3.1 Thyristor power controller[edit | edit source]

  • Electronic supply:
The electronics of the control device is supplied by a seperate connection with 230V~/110V~.
The connection is made at terminals X4.1 and X4.3. Terminals X4.1 and X4.2 along with X4.3 and X4.4 are internally bridged for alternative connection option.
  • Power supply and load:
Make sure that the load (IR-heater) is connected to the Terminal T1 and N.
The Controller Power supply 230V~/400V~ should be connected to the Terminal L1. On Terminal X1.1 connect N or the other middle phase. When connecting to a phase a 2A slow acting fuse is required, at N the connection can be made directly.
Terminals X1.1 and X1.2 are internally bridged.
Terminals X22.1...X22.4 are used for the communication to the bus module.

3.1.1 Connection diagram Thyro-AX 1A[edit | edit source]

File:Connection diagram.png
Thyro-AX 1A


3.1.2 Power controller connecting terminals overview[edit | edit source]

File:Connecting terminals (overview).png


3.2 Bus Module Profinet[edit | edit source]

  • Electronic supply:
Make sure that the connection of the external 24V power supply is made at the terminals X11.1(+) and X11.2(-).Ground to X11.3.
  • Connecting the Power Controller to X1-X8 of the Bus Module:
Switch off the main Power Supply including the external 24V Power source.
Connect the interfaces X1 to X8 of the bus Module to the system interfaces of the Power controller.
Make sure a shielded four wire cable is connected at the terminals X22.1...X22.4 of the power controller to X1.1...X1.4 of the bus module.
  • Bus Module connection to the Master (PLC):
One of the Ethernet ports at Terminal X202 has to be connected to the PLC or to a switch.
To connect to Thyro-Ax module, A standard patch cable (straight) is required for direct connecting with a Thyro-Ax Module. For a connection via switch, a cross-over cable is required.

3.2.1 Bus module connecting terminals overview[edit | edit source]

File:Bus Module Connecting terminals (overview).png


4 Display and operational elements[edit | edit source]

With the touch display all the parameters could be changed. By pressing the icon Menu at the bottom of the display you will reach the parameter list.
Select a specific parameter by choosing it, another list will show up where changing the parameter values is possible.
By pressing at the upper part of the display. It will show over several screens the current Values.

File:Touch display.png


Template:Notice bms

5 Commissioning and configuration[edit | edit source]

5.1 Thyristor power controller[edit | edit source]

Template:Notice bms

5.1.1 Functionality and Operating Modes[edit | edit source]

The Thyro-Ax is equipped with a variety of functions, so it can be fitted to the desired application.
For optimal adaptation to different applications or varying electrical loads the appropriate operating mode can be selected by the User.

Following modes could be selected:

  1. Full Wave Mode Takt
  2. Phase Angle Firing Var (Only Thyro-AX 1A and 3A)
  3. SST ramp in operating mode Takt
  4. Quick Takt Mode Qtm (Only Thyro-AX 1A)
  5. Switch Mode Switch
  • Select the Quick Takt Mode QTM operating mode, because of its high control dynamics.
  • Settings->Operating->QTM.
  • Or set to VAR like shown below.
File:Operating Modes.png
Operating modes


Template:Notice bms

5.1.2 Control modes[edit | edit source]

The Control Mode has default Value “U” - Voltage regulation.

  • Set the control Mode to U² = (U X U) for a better performance calculation.
File:Control mode diagram.png
File:Control modes.png
Control mode


5.1.3 Limitations[edit | edit source]

In addition to the configured control mode the following variables can be limited:

-Voltage limitation (U)
-Current limitation (I)
-power limitation (P)
  • Set the voltage limitation (U) to the supply voltage accordingly (400V/600V).
  • Set the current limitation (I) to the nominal current of the load.
  • Set the power (P) to the nominal power of the load.

Example:

  • U = 600V
  • I = 20A
  • P = 12kW
File:Limitations.png
Limitation



5.1.4 Load monitoring[edit | edit source]

The load monitoring is a function to identify a breakdown or wire break of one or more resistors connected in parallel series. Therefore the values of load resistance characteristic have to be in the device.

Values Set: Several ways to adjust the Load resistence (R_Max):

  • TeachIn function (preferred): the load characteristic will be measured automatically.
Preparations for the TeachIn:
  • Connect with the Thyro-Tool and adjust the monitoring and R auto wait like shown in the picture below.
    • Activate Rmin, Rmax, Ipeak max and Temperature unit max
  • The R auto wait is the measuring time for the TeachIn. Set to 120s. Within 120s the temperature is high enough for a stable resistor.
File:Thyro-AX-TeachIn1.PNG


  • TeachIn
Execute like following: Menu-->TeachIn

*Check that the Thyro-AX controller runs stable at 100% controller output!!!

In case of errors at 100% output, adjust the Rmax limit manually!!!
  • Manual entry of load resistor value via Display: It will shows the arithmetic mean of 10 values of the resistor characteristics.
Menu-->Settings-->Monitoring.

you can see the defined resistor values in the software Thyro-Tool AX: see first (Thyro-Tool AX software).

File:Thyor Tool AX devices R MAX.png


Under Regulation -> Monitor deselect all. The temperature unit maximum will be set automatically for devices safety.

Set like shown.

File:Thyro-AX-Regelung.PNG

If a heater is not working anymore or has a wire break following message in Thyro-Tool AX Software and in PVSS will appear and the display screen will turn red.

Template:Notice bms

5.1.5 Pulse inhabitation[edit | edit source]

Make sure the bridge is installed between the terminals X2.2 and X2.1. In case of missing connection the pulse inhabitation is activated, which means the current does not flow anymore.
By missing connection the touch display turns red and in the data logger "pulse on" is listed.

5.1.6 Parameter save/load[edit | edit source]

The Parameter Settings can be done either by the touch display or by using the Thyro-Tool-AX Software.
Use the Ethernet port to establish a connection between a PC and the Thyristor controller.

File:USB Ethernet ports.png
























1.Ethernet Port
2.USB Ports


5.1.6.1 Write/Read parameter via USB[edit | edit source]

The parameters can be also transferred from one device to another of the same type by using a USB stick.

Write parameter from device to USB-stick:

  • Plug in a USB-stick.
A message will show up and asks to disable the Output--> pulse inhabitation will be activated (means no current flow).
  • Agree with OK, the display turns red.
  • Select write parameter to download file from Device--> USB-stick.
  • After parameter are downloaded, the message "DONE" will be shown.
  • Unplug the USB-stick, agree the message to activate the output with OK. Device will turn to normal operation again.


Read parameter from USB-stick to Device:

  • Plug in a USB-stick.
A message will show up and asks to disable the Output--> pulse inhabitation will be activated (means no current flow).
  • Agree with OK, the display turns red.
  • Select read parameter to download file from USB-stick--> Device.
  • Agree the message "Save to EEPROM" after downloading the parameter.
  • unplug the USB-stick, agree the message to activate the output with OK. Device will turn to normal operation again.


The supply voltage is not always displaying the value (e.g.400V) in PVSS but shows up after switching on the thyristor. That is related to the fact that the Thyro-AX is measuring The voltage on the load side and then determined by the modulation of the supply voltage. Since the accuracy increases with increasing modulation of the line voltage, the supply voltage is not displayed at low power levels.

File:Pvss input supply voltage.png

5.2 Bus module Profinet[edit | edit source]

5.2.1 Protocol and slots settings[edit | edit source]

  • Assign the IP and the Device name in the HW-Configuration. Details see:Public:Sinamics Network Configuration
  • Set the rotary switch "Protocol" to 0 for profinet.
  • Set the rotary switch "Slots" to the number of Power controller (up to 8) which are connected to the bus module.
For changing the number of the used slots, the rotary switch must be turned first to 0 and then you have 2 sec. time to set a new number after leaving the position 0.

Template:Notice bms

5.2.2 Operating display of the bus module[edit | edit source]

File:Operating display of bus module.png

5.3 Thyristor TCP/IP Configuration[edit | edit source]

there are two options, 1. manualy, 2. config file
  • 1 Goto Settings with buttons: Ethernet acording Network sheme (10.XX.YY.180 ,181 ,182 ,183... continiue.).
                               IP-address -> 10.XX.YY.180...
                               SubNetMask -> 255.255.255.0
  • 2 In the Thyro AX Software last parameters are network settings,
    • 1.set Network parameters
    • 2.safe file
    • 3.upload via USB

6 Thyro-Tool AX software[edit | edit source]

The Software Tyhro-Tool AX is for parameterization and visualization of connected devices of series Thyro-AX. You can use it for setting the parameter instead of the touch display. By using the Software a remote maintenance is easier and we have the maximum control over the devices. To Establish a connection to the device, a direct connection or a line connection to the machine Network is required.

6.1 installation[edit | edit source]

  • Execute the Thyro-Tool AX.exe
  • After installing it is necessary to restart the pc so the windows service can start!

6.2 Connection to local installed server[edit | edit source]

  • Open the Software, a connection to the local server on the device will be established immediately.
following message will be shown at the bottom if the connection was successfull:
File:EN connection established.png
  • Click at the icon Tools and select looking for devices in the network
File:Thyor Tool AX devices in the network.png

6.3 Parameter settings[edit | edit source]

  • All parameters which can be adjusted with the touch display, could be adjusted by the Software as well.
  • If a value is changed it will turn red and it is directly active. Use the button save to keep the changes active even after restarting the device.

6.4 extended settings[edit | edit source]

enable the extended settings at Tools > enable extended range of functions
Password is in

 new Thyro AX Versions: aei<date><hour>
 and in older Versions: aeg<date><hour>
 for example: "aei2709"


7 Firmeware update[edit | edit source]

7.1 Thyro-AX[edit | edit source]

The firmeware version should match the latest version TA3AX16P.E00.dfu. You can check it by two ways:

1. LCD display: Click on the upper part of the display until the last menu before you return to start menu again:

File:Thyro AX Firmwareversion LCD Check.png

2. Thyro-Tool-AX Software: Parameters-->General

File:Thyro AX Firmwareversion ThyroTOOL Check.png

If the actual firmware version does not conform the latest version, please proceed like following:

  • Run DfuSe_Demo_V3.0.2_Setup.exe or DfuSe_Demo_V3.0.2_Setup_amd64.exe as administrator (right click, run as…).
  • Click Next
  • Finish the installation of DfuSe and the virtual port drivers.
  • Disconnect mains-supply, control-supply and USB-5V-supply from Thyro-AX.
  • Open the complete front door (not just the little one for the connections).
  • Next to the USB-ports there is a 3 pin connector with a jumper.
  • Remove the jumper and use it to shorten the inner 2 pins for firmware update.
File:Thyro AX FirmwareUpdate jumper.png
  • Connect the original USB-cable to PC. The display remains dark, but the internal voltage LED show if the unit is powered via USB.
File:Thyro AX FirmwareUpdate USB LED.png
  • Run the DfuSe Demo V3.0.2 program.
File:Thyro AX FirmwareUpdate DfuSe Program1.png
  • Click "Choose…" in the Upgrade or Verify Action field and select latest firmware: TA3AX(XXX).E(YY).dfu
The (XXX) and (YY) are standing for the firmware version, latest version is TA3AX16P.E00.dfu

Template:Notice bms

  • Click upgrade
File:Thyro AX FirmwareUpdate DfuSe Program4.png
  • After the message "Upgrade successful!" appears, click quit.
  • Disconnect USB-cable.
  • Remove jumper and use it to shorten the 2 outer pins for normal operation (as it was before).
  • Close the front door and repower the unit.

8 New Advanced Energy Profinet Card[edit | edit source]

Before the Profinet communication is working you need to activate the anybus modul slot:

  • Download the Programm "Thyro Tool Pro" from Advanced Energy Plattform
  • Connect the USB cable from the microUSB Port in front of the panel to your computer
  • It automatically find the COM-Port and will connect to the modul
  • adapt this setting below in the picture
  • after you change it, you will see the RJ45 Port start blinking
File:Thyro AX new Advanced Energy Profinet Card.JPG
File:Thyro AX new Advanced Energy Profinet Card Hardware settings.JPG


9 Troubleshooting[edit | edit source]

9.1 Thyro AX is not Reading/Writing parameter file via USB[edit | edit source]

  • Check if the latest firmware version is installed on the Device.
For upgrading the Firmware, see (Firmware update).

9.2 Frequency tolerance exceeded error[edit | edit source]

If the controller shows "frequency tolerance exceeded" error and the heaters goes off due to that error, increasing the frequency tolerance range would be a solution.

File:Thyro AX frequency tolerance error.JPG

Steps to increase the tolerance range

1. Connect to the controller
2. Enable extended range of functions
File:Thyro AX enable extrended range of functions.JPG
3. Type the Password accordingly (aeg+actual day+actual hour) (aeg[DD][HH]).
For example date of the day is 11/16/2017 and time is 07:54 AM Password: aeg1607
File:Thyro AX enable extrended range password.JPG
4. After enabling extended range select Tools-> manual parameter query…
File:Thyro AX manual Parameter .QueryJPG.JPG
5. Select the controller and type in the field Link the address of the frequency tolerance range parameter 0_0_75_0_3, change the correspondent value from default value 5 to e.g. 10 and send then save the new configuration to the controller
File:Thyro AX tolerance range parameter.JPG

9.3 Overview of fault, status and monitoring messages[edit | edit source]

File:Overview of fault, status and monitoring messages.png
Overview of fault, status and monitoring messages