1 Test equipment[edit | edit source]

The Video signal output is a composite signal which most monitors can handle. Only you might need a BNC to Chinch Plug.

Template:Image

If you don't have a cable like this, you can easily assemble one adapter by yourself. It is recommended that you use a monitor next to the camera for the adjustments


BMS Test system:

Template:Image

2 Camera Setting[edit | edit source]

  • Adjust the Dip Switches (S1) to
Dip Description Setting
1 AGC Hi/Low OFF
2 Gamma correction OFF
3 BLC ON
  • Set Dial (S2) to 8 for Auto Iris adjustment
    • If the Surrounding is to dark, the Iris asjustment might not work properly. Then switch the dial to 7 for highest sensitivity

Template:Image

  • Adjust the gain (S3) to the environment for best results

Template:Image

3 Focus Adjustment[edit | edit source]

  • When working at the optical parts, take care to keep them clean!

Template:Notice bms

  • Open Screw (S1) to take out the camera from the telescope
  • Make sure that the Teflon Adaptper is tightend to the camera

Template:Image

  • Set that camera back to the housing and adjust the Focus with the distance (D1)

Template:Image

  • When Focus is right, tight the screw (S1) by hand only!

4 Mirror adjustment[edit | edit source]

Template:Notice bms

  • Open the screw S4

Template:Image

  • Adjust the mirror by changing the position in the housing with our finger